The Inverter Introduction
The UPS Inverter system designed to use in the area where the grid power supply is not stable with DC charger for 12V 24V for battery, Stable Voltage and UPS function together, it can be compatible to PV MPPT for household power back up. Compared With PPS, this inverter system have almost function and much better cost advantage with more flexible choices for battery power.
The Main Features
• Stable Voltage: The Input fluctuated AC voltage range 150-256V, keep the output 220V to protect the household appliances.
• UPS Function: The inverter integrate with UPS to protect the important appliance, when the SOC of battery is enough to discharge power and the grid is cut off, the output power will keep 220V from battery power.
• DC Charger Function: The inverter integrated with DC Charger for 12V 24V 20A to charge LiFePO4 battery, provide more choices for client to pick different battery.
• MPPT Optional: The inverter is compatible to MPPT 12V 24V 10A 20A PV System.
Main Applications
•The UPS inverter is widely use to household back up system, especially in the area where the power supply is not stable, because the ups inverter can protect the appliances from burned by fluctuated lower;
•The UPS can be used as UPS to protect important device for cutoff power power outage effect, such as company engineering computer service or designer computer;
•The inverter can be integrated with MPPT 12V 24V 20A to build an off grid power system for household use, it is good to use in the area without grid power supply.
Main Parameters
SPECIFICATION | Model | 500VA | 800VA | 1000VA | 1500VA | 2500VA | 3000VA |
Power | 350W | 500W | 700W | 1050W | 1400W | 2100W | |
INPUT | Voltage range | AC150-265V | |||||
Frequency range | 50Hz/60Hz | ||||||
OUTPUT | AC Voltage Regulation (Batt. Mode) | AC220V±25V | |||||
Frequency range (Batt. Mode) | 50Hz/60Hz | ||||||
Wave form | Pure Sine Wave | ||||||
BATTERY | Battery Type(External) | 12V | 24V | ||||
Rated battery voltage | 12VDC(10-16V) | 24VDC(20-32V) | |||||
Charge Modes | 3 stage:bulk,boost,float | ||||||
Charging current | DC15A | DC20A | DC25A | ||||
Protection | Overload,Overheat,Output high/low voltage,Battery low voltage, Short-circuit,Over-charge,Over-discharge | ||||||
GENERAL PARAMETER | Switch time | 10ms | |||||
Operating Humidity | 10-90% | ||||||
Operating Temperature | 0℃~+40℃ | ||||||
Class Protection | IP20 | ||||||
Dimension DxWxH(mm) | 146x237x170 | 146x338x170 | 146x338x170 | ||||
Net Weight | 8KG | 11.5KG | 17.5KG | 19.66KG |